Part Number Hot Search : 
CNQ04 NTE1541 L0822 TA0426A V257F IRF14 CNQ04 4752A
Product Description
Full Text Search
 

To Download B84144A0016R120 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 4-line filters for converters and power electronics
520/300 V ac, 50/60 Hz, 8...200 A, 50 C
Ordering code: Date: Version:
B84144A0008...A0200R120 2009-01-16 09
(c) EPCOS AG 2008. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited.
4-line filters for converters and power electronics
B84144A0008...A0200R120
Construction S 4-line filter S Metal case Features S Easy to install S Compact design S Design complies with IEC 60939 S cULus, ENEC approval S Optimized for long motor cable and operation under full load Applications S Frequency converters for motor drives, e.g. - elevators - pumps - traction systems - conveyor systems - HVAC systems (heating, ventilation and air conditioning) S Power supplies Terminals S Line side: finger-safe terminal blocks S Load side: finger-safe terminal blocks Marking S Marking on component: manufacturer's logo, ordering code, rated voltage, rated current, rated temperature, climatic category, date code S Minimum marking on packaging: maufacturer's logo, ordering code, date code, quantity
1)
To IEC 60529:2001
Please read and Cautions and warnings and Important notes at the end of this document.
Page 2 of 15
B84143-A*-R120-09-7659
4-line filters for converters and power electronics
B84144A0008...A0200R120
Typical circuit diagram LINE L1 L2 L3 LOAD L1' L2' L3'
N
N'
Technical data and measuring conditions Rated voltage Rated frequency Test voltage line to line for 2 s Test voltage line to case for 2 s Rated temperature Overload capability (thermal) for 3 min per hour or for 30 s per hour Climatic category (IEC 60068-1) UR fR Utest Utest TR 520/300 50/60 2240 2720 50 1.5 x IR 2.5 x IR 25/100/21 V AC Hz V DC V DC C
Please read and Cautions and warnings and Important notes at the end of this document.
Page 3 of 15
B84143-A*-R120-09-7659
4-line filters for converters and power electronics
B84144A0008...A0200R120
Characteristics and ordering codes IR
Terminal cross section
Ileak 2)
Rtyp
Approx. weight kg 1,55 1,6 1,7 2,15 2,2 3,6 5,1 9,5 11,7 12,5
Ordering code
Approvals
A 8 16 25 36 50 66 90 120 150 200
mm2 4 4 4 10 10 16 25 50 95 95
mA <3,5 <3,5 <3,5 <3,5 <3,5 <3,5 <3,5 <3,5 <3,5 <3,5
m 13,6 7,5 3,9 2,7 1,3 1,1 0,76 0,47 0,32 0,23
B84144A0008R120 B84144A0016R120 B84144A0025R120 B84144A0036R120 B84144A0050R120 B84144A0066R120 B84144A0090R120 B84144A0120R120 B84144A0150R120 B84144A0200R120
x x x x x x x x x x
x x x x x x x x x x
x x x x x x x x x x
X = approval granted
2) 3 phase operation in TN network; maximum voltage = UR; frequency = 50 Hz without harmonics; tolerance of capacitors -20%/ 0%; worst case positioning of the components; unbalance 2% according EN 50160:2000.
Please read and Cautions and warnings and Important notes at the end of this document.
Page 4 of 15
B84143-A*-R120-09-7659
4-line filters for converters and power electronics
B84144A0008...A0200R120
Dimensional drawings B84144A0008R120 B84144A0016R120 B84144A0025R120
60 2 80 65$0,3
225$0,5 6,5
200
238
12
45
All dimensions in mm!
Please read and Cautions and warnings and Important notes at the end of this document.
Page 5 of 15
Tightening torque of screw 0,65 - 0,8Nm
Tightening torque 2 0,1 Nm
PE M5x19
Terminals 4mm2
80
B84143-A*-R120-09-7659
4-line filters for converters and power electronics
B84144A0008...A0200R120
B84144A0036R120 B84144A0050R120
60 2
90 75$0,3
6,5
Tightening torque 3 0,15 Nm
12
45 All dimensions in mm!
Please read and Cautions and warnings and Important notes at the end of this document.
Page 6 of 15
Tightening torque of screw 1,2 - 1,5Nm
PE M6x24
Terminals 10mm2
90
B84143-A*-R120-09-7659
257$0,5 272
230
4-line filters for converters and power electronics
B84144A0008...A0200R120
B84144A0066R120
32,3
80 10 (2)
100 85$0,3
32,3
290 275$0,5 6,5 Tightening torque 3 0,15 Nm 41 12
260
20,3 11
40 All dimensions in mm!
Please read and Cautions and warnings and Important notes at the end of this document.
Page 7 of 15
B84143-A*-R120-09-7659
Tightening torque of screw 2 - 2,3Nm
Terminals Phoenix HDFK16
100 64,5
PE M6x24
4-line filters for converters and power electronics
B84144A0008...A0200R120
B84144A0090R120
100 (2)
130 115$0,3
Tightening torque 6 0,3 Nm
38,5
6,5
PE M8x29
20
20
(48,5)
(10,2)
All dimensions in mm!
Please read and Cautions and warnings and Important notes at the end of this document.
Page 8 of 15
Tightening torque of screw 4 - 4,5Nm
Terminals Phoenix HDFK25
(93,1)
130
B84143-A*-R120-09-7659
265$0,5 280
250
4-line filters for converters and power electronics
B84144A0008...A0200R120
B84144A0120R120
130
130 115$0,3
(2)
Tightening torque 10 1 Nm
PE M10x39
(43)
6,5
20
20
(54)
(20)
All dimensions in mm!
Please read and Cautions and warnings and Important notes at the end of this document.
Page 9 of 15
Tightening torque of screw 6 - 8Nm
Terminals Phoenix HDFK50
96,8
130
B84143-A*-R120-09-7659
265$0,5 280
250
4-line filters for converters and power electronics
B84144A0008...A0200R120
B84144A0150R120 B84144A0200R120
(50,5)
130 100,7
160 145$0,5
(2)
6,5 13,5
Tightening torque of screw 15 - 20Nm
Terminals Phoenix HDFK95
80
All dimensions in mm!
Please read and Cautions and warnings and Important notes at the end of this document.
Page 10 of 15
17
B84143-A*-R120-09-7659
Tightening torque 10 1 Nm
PE M10x39
160
115
265$0,5 280
(250)
4-line filters for converters and power electronics
B84144A0008...A0200R120
Insertion loss (typical values at Z = 50 W) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical)
B84144A0008R120 100 dB a 80 a 80 100 dB
B84144A0016R120
60 40 20
60 40 20
0 104
105
106
107 f
Hz 108
0 104
105
106
107 f
Hz 108
B84144A0025R120 100 dB a 80 a 80 100 dB
B84144A0036R120
60 40
60 40
20
20
0 104
105
106
107 f
Hz 108
0 104
105
106
107 f
Hz 108
Please read and Cautions and warnings and Important notes at the end of this document.
Page 11 of 15
B84143-A*-R120-09-7659
4-line filters for converters and power electronics
B84144A0008...A0200R120
Insertion loss (typical values at Z = 50 W) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical)
B84144A0050R120 100 dB a 80 a 80 100 dB
B84144A0066R120
60 40 20
60 40 20
0 104
105
106
107 f
Hz 108
0 104
105
106
107 f
Hz 108
B84144A0090R120 100 dB a 80 a 80 100 dB
B84144A0120R120
60 40
60 40
20
20
0 104
105
106
107 f
Hz 108
0 104
105
106
107 f
Hz 108
Please read and Cautions and warnings and Important notes at the end of this document.
Page 12 of 15
B84143-A*-R120-09-7659
4-line filters for converters and power electronics
B84144A0008...A0200R120
Insertion loss (typical values at Z = 50 W) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical)
B84144A0150R120 100 dB a 80 a 80 100 dB
B84144A0200R120
60 40 20
60 40 20
0 104
105
106
107 f
Hz 108
0 104
105
106
107 f
Hz 108
Please read and Cautions and warnings and Important notes at the end of this document.
Page 13 of 15
B84143-A*-R120-09-7659
4-line filters for converters and power electronics
B84144A0008...A0200R120
Caution and warnings S Please note the advices in our data book "EMC Filters" (latest edition); attention should be paid to the chapter "General safety notes". S It shall be ensured that only qualified persons (electricity specialists) are engaged on work such as planning, assembly, installation, operation, repair and maintenance. They must be provided with the corresponding documentation. S Danger of electric shock. EMC filters contain components that store an electric charge. Dangerous voltages can continue to exist at the filter terminals for longer than five minutes even after the power has been switched off. S The protective earth connections shall be the first to be made when the EMC filter is installed and the last to be disconnected. Depending on the magnitude of the leakage currents, the particular specifications for making the protective-earth connection must be observed. S Impermissible overloading of the EMC filter, such as with circuits able to cause resonances, impermissible voltages at higher frequencies etc. can lead to bodily injury and death as well as cause substantial material damages (e.g. destruction of the filter housing). S EMC filters must be protected in the application against impermissible exceeding of the rated currents by overcurrent protective. S In case of leakage currents > 3.5 mA you shall mount the PE conductor stationary with the required cross section before beginning of operation and save it against disconnecting. For leakage currents IL 4) < 10 mA the PE conductor must have a KU value 3) of 4.5; for leakage currents IL q 10 mA the PE conductor must have a KU value of 6.
3) The KU value (symbol KU) is a classification parameter of safety-referred failure types designed to ensure protection against hazardous body currents and excessive heating. A value of KU = 4.5 with respect to interruptions is attained: - with a permanently connected protective earth circuit w 1.5 mm2 - with a protective earth circuit w 2.5 mm2 connected via shroud connectors (IEC 60309-2). KU = 6 with respect to interruptions is achieved for fixed-connection lines w 10 mm2 where the type of connection and line layout correspond to the requirements for PEN conductors as specified in relevant standards. 4) IL = leakage current let-go
Please read and Cautions and warnings and Important notes at the end of this document.
Page 14 of 15
B84143-A*-R120-09-7659
4-line filters for converters and power electronics
B84144A0008...A0200R120
Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statement cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before end of their usual service life time cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSSP, CTVS, DSSP, MiniBlue, MKK, MLSC, MotorCAP, PCC, PhaseCap, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks.
1
Please read and Cautions and warnings and Important notes at the end of this document.
Page 15 of 15
B84143-A*-R120-09-7659


▲Up To Search▲   

 
Price & Availability of B84144A0016R120

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X